Description
Multiparameter Meter, pH 0 to 14, Electric Conductivity 0 to 200 ms/cm, TDS 0 to 100 g/L, ORP -1999 to 1999 mV, Dissolved Oxygen 0 to 50 mg/L, Oxygen Concentration 0 to 500%, Salinity 0 to 70 ppt, Ion Specific Electrode Ammonium and Nitrate, 0 to 200 mg/L, Second Ion Specific Electrode Chloride 0 to 1000 mg/L, Temp -5 to 70 C, Memory 5000 Data Sets, Barometric Pressure 400 to 999.9 mmHg, Includes Data Manager Software, USB Cable, Pro Comm II Communications Saddle, Batteries and Instructions
| |
Item : Multiparameter Meter
pH Range : 0 to 14
Electric Conductivity Range : 0 to 200 ms/cm
TDS Range : 0 to 100 g/L
ORP Range : -1999 to 1999mV
Dissolved Oxygen Range : 0 to 50 mg/L
Oxygen Concentration : 0 to 500%
Salinity Range : 0 to 70 ppt
Temp. Range (F) : 23 to 158
Temp. Range (C) : -5 to 70
Ion Specific Electrode Range : Ammonium and Nitrate, 0 to 200 mg/L As Nitrogen
Second Ion Specific Electrode Range : Chloride 0 to 1000 mg/L
Display : Graphic LCD
Barometric Pressure Range : 400 to 999.9 mmHg
Auto Power Off : Yes
Memory : 5000 Data Sets with Good Laboratory Practices Data
|
Temperature Compensation Range : 0 to 45
Calibration : Parameter Specific
pH Accuracy : +/-0.1
ORP Accuracy : +/-20 mv
Oxygen Concentration Accuracy : (0 to 200%) +/-2% of Reading or 2% Air Saturation Whichever is Greater, (200 to 500%) +/-6% of Reading
Salinity Accuracy : +/-1.0% of Reading or 0.1 ppt Whichever is Greater
Temp. Accuracy : +/-0.2 C
Second Ion Specific Electrode Accuracy : Chloride +/-15% of Reading or 5 mg/L-N Whichever is Greater
Electric Conductivity Resolution : 0.001 ms/cm to 0.1 ms/cm, Range Dependent
pH Resolution : 0.01
TDS Resolution : 0.001, 0.01, 0.1 g/L
ORP Resolution : 0.1mV
Dissolved Oxygen Resolution : 0.1 or 0.01 mg/L, selectable
Oxygen Concentration Resolution : 1% or 0.1% Air Saturation, Selectable
Salinity Resolution : 0.01 ppt
Temp. Resolution : 0.1 C
|
Ion Specific Electrode Resolution : Ammonium and Nitrate 0.1 mg/L
Second Ion Specific Electrode Resolution : Chloride 0.1 mg/L
Interface : USB
Power Source : 2 C Batteries or USB
Manufacturers Warranty Length : 3 Years
Displayed Temperature Range : -5 to 70 Degrees C
Automatic Temperature Compensation : Yes
Sub-Category : Handheld
Operating Temp. Range (C) : -5 to 70 Degrees
Waterproof : Yes
Operating Temp. Range (F) : 23 to 158 Degrees
Dissolved Oxygen Range Accuracy : (0-20 mg/L) +/-2% of Reading or 0.2 mg/L Whichever is Greater, (20 to 50 mg/L) +/-6% of Reading
Includes : Data Manager Software, USB Cable, Pro Comm II Communications Saddle, Batteries and Instructions
Ion Specific Electrode Accuracy : Ammonium and Nitrate +/-10% of Reading or 2 mg/L-N Whichever is Greater
Electric Conductivity Accuracy : +/-0.5% of Reading or 0.001 ms/cm, Whichever is Greater; +/-1% of Reading or 0.001 ms/cm on Cables Over 20 Meters Long
|
|
|
|
|